FINECO Encapsulated Steel Data Center ah hian a sang ber a ni
Data Center, Server Room & IT Facilities pawimawh tak takte tan Duty Access Flooring rit tak tak-
FINECO Encapsulated Steel Raised Floor hi modular access flooring system a ni a, data center, server room, leh technical environment hrang hranga structural load performance, underfloor service access, leh long-term stability mamawhna atana siam a ni.
He system hian steel panels fully enclosed, engineered core, leh adjustable steel pedestals te a integral a ni. Hei hian power distribution, data cabling, leh cooling infrastructure atan accessible underfloor void a siam a, chutih rualin high-density IT equipment a support bawk.
Technical lam thil chi hrang hrang
|
Parameter a ni |
A sawifiahna |
|
Product chi hrang hrang |
Encapsulated Steel atanga siam chhuah a ni |
|
Dilna hmasa ber |
Data Center, Server Room, Telecom hmanrua te a awm bawk |
|
Standard Panel Size a ni |
600 × 600 mm a ni |
|
Panel Thickness a ni |
30 mm - 35 mm (A duh angin a siam theih) |
|
Panel siam a ni |
Welded Steel Top & Bottom Sheets te chu a inkhar kim vek a ni |
|
Core Material a ni |
High-Density Particle Board / Cementious Core hmanga siam a ni |
|
Surface Finish a ni |
HPL / PVC / ESD Vinyl / Bare Steel hmanga siam a ni |
|
Panel rit zawng |
Kg/m2 vel. 12 - 15 vel a ni |
|
Concentrated Load a ni |
3.0 kN - 4.5 kN (Class 1 – Class 3) a ni a, a man pawh a tlawm hle. |
|
Uniform Distributed Load a ni |
10 - 15 kN/m2 a ni |
|
Finished Floor san zawng (FFH) 1.1. |
150 mm - 1500 mm a ni |
|
Pedestal hnuai lam atanga siam a ni |
High-Strength Galvanized Steel a ni a, Optional Stringers a awm bawk |
|
ESD hnathawh dan |
Dissipative (106 - 109 Ohms) emaw Conductive (104 - 106 Ohms) emaw a ni thei. |
|
Kangmei chi hrang hrang |
Meialh darh Class A / Class 0 a ni |
|
Dan zawm dan tur |
EN 12825 / CISCA Section 5 / ASTM E84 hmanga tihchhuah a ni |
Thil siam chhuah dan (Product Structure) a ni
Encapsulated Panel Assembly neih dan tur chu:Top leh bottom welded steel sheet te hian high-density engineered core a huam a, edge protection kimchang tak, moisture sealing, leh long-term structural durability a pe a ni.
Steel Pedestals siamrem theih te:High-strength galvanized steel base plate leh vertical threaded stems atanga siam a ni a, hei hian floor leveling dik tak a siam thei a, floor heights 150 mm atanga 1500 mm thlenga tihfel theih a ni.
Grid-Pedestal Lu lock theihna:Panel pakhat zel chu 600 × 600 mm modular grid nghet takah him takin lock la, chutih rualin structural slab-a weight distribution inang tlang tak a awm theih nan.
Steel Stringers duhthusam:Snap-on emaw bolted steel stringers hian pedestal heads te chu a thlunzawm a, hei hian heavy equipment zone tan lateral stability, torsional rigidity, leh rolling load performance nasa takin a tipung a ni.
Product a thatna te
Steel Encapsulation kimchang tak siam a ni:Top leh bottom steel sheet inkharkhip te hian maintenance access fo laiin core chu moisture, heavy impact, leh wear lakah a venghim a ni.
Integrated Load Stability a awm theih nan:Precision-formed panels, adjustable steel pedestals, leh optional stringers te inzawmkhawm hian rolling leh concentrated server rack loads laka resistance sang tak a siam a ni.
Rapid Maintenance hman theihna tur:Panel pakhat zel chu suction lifter hmangin a chhuak nghal a, hei hian a kianga infrastructure tibuai lovin cable re-routing emaw equipment upgrade emaw chak tak a phalsak a ni.
Airflow enkawl dan tha ber:Solid panels te hi perforated emaw adjustable grille panels nen seamless takin an inzawm khawm a, underfloor cooling strategy dik tak a support thei a ni.
Quality Assurance khauh tak neih a ni:Multi-stage quality control hnuaia siam niin steel stamping, encapsulation sealing, leh dimensional tolerance check te a huam a ni.
Product hman dan tur
Hyperscale & Colocation Data Center hrang hrangte chu:Server configuration thlak danglam theihna tur high-density equipment support leh flexible layout a pe.
Enterprise Server Room hrang hrangah:Corporate IT infrastructure leh power distribution unit hrang hrangte tan platform nghet leh inrual tak a pe chhuak thin.
Telecom & Network-a hman theih turte:High{0}}volume fiber-optic cabling leh inbiakpawhna hardware rit tak tak a enkawl.
Control Room leh Technical hmun hrang hrang:24/7 mission-critical operations atan service integration thianghlim leh maintenance awlsam taka hmuh theihna a siam.
Airflow enkawl dan & Underfloor Voids te
Underfloor Voids te chu:Power conduit -capacity sang tak, cable tray, leh busbar te a awm thei.
Ventilation duhthlan tur hrang hrang:Solid panels te hi perforated steel panels (25% atanga 50% open area) emaw adjustable grille panels te nen an inzawm khawm a, underfloor cooling mamawh leh hot/cold aisle containment nena inmil a ni.
Quality Control & Export Logistics te a ni
Thil siam dan dik tak:Multi-stage inspection khauh tak hian steel stamping, automated encapsulation, flatness, leh load testing te a huam a ni.
Export-Grade hmanga thil siam chhuah:Steel panel te hi international container shipping (FCL/LCL) chhunga edge chhiatna awm lo turin moisture-sealed leh palletized an ni.
Zawhna Zawh fo thin
Q: Encapsulated steel raised floor chu eng nge ni?
A: Modular access floor panel a ni a, engineered core hualtu top leh bottom steel sheet fully welded a ni a, adjustable steel pedestal-ah dahin accessible underfloor service void siam a ni.
Q: System hian server rack rit tak tak a support thei em?
A: Ni e. He system hi concentrated leh rolling load rit tak tak tan engineer a ni. Performance hi panel, pedestal, stringer, leh structural slab te integrated assembly anga teh a ni a, chu chu equipment weight bik nena inmil turin a ni.
Q: Ventilated panels hi cooling atan a awm em?
A: Ni e. Solid panels hi perforated steel panels (25% atanga 50% open area) emaw, underfloor cooling mamawhna nena inmil tur adjustable grille panels emaw nen pawh hman theih a ni.
Q: Floor hi ESD-sensitive environment atan a tha em?
A: Ni e. Configuration-ah hian conductive emaw dissipative surface finish te pawh a awm thei a, grounding option bik hmangin sensitive IT hardware electrostatic discharge atanga venhimna a awm thei bawk.
Q: Quotation dawng tur chuan eng information nge mamawh?
A: Khawngaihin i project area zawng zawng (m2), Finished Floor Height (FFH), load capacity mamawh, surface finish duh zawng, ventilation ratio, leh destination port te pe rawh.
hot tags .: encapsulated steel data center raised floor, China encapsulated steel data center raised floor siamtute, supplier te, factory te an ni