Encapsulated Steel Heavy-Duty hmanga tihsan a ni

Inquiry thawn rawh .
Encapsulated Steel Heavy-Duty hmanga tihsan a ni
Kimchang
He system hian fully encapsulated steel panel leh adjustable steel pedestal leh optional heavy-duty stringers te a thlunzawm a ni. Hei hian high-density power cable, data network, leh HVAC airflow te tan floor hnuaiah accessible plenum a siam a ni.
Bithliahna
Encapsulated Steel atanga siam a ni
Share to
Hrilhfiahna

FINECO Encapsulated Steel Heavy-Duty hmanga tihsan a ni

 

Data Center, Server Room leh Technical Facilities te tan High-Load Access Flooring a awm bawk
FINECO Encapsulated Steel Heavy-Duty Raised Floor hi modular access flooring system a ni a, floor loading sang tak, structural stability, leh underfloor service access theihna tura engineer a ni.
He system hian fully encapsulated steel panel leh adjustable steel pedestal leh optional heavy-duty stringers te a thlunzawm a ni. Hei hian high-density power cable, data network, leh HVAC airflow te tan floor hnuaiah accessible plenum a siam a ni.

 

Thil pawimawh tak tak

 

Heavy-Duty Load hnathawh dan:Concentrated leh heavy rolling equipment load hnuaia technical space-a engineer a ni.
Fully Encapsulated Steel Design hmanga siam a ni:Welded steel shell hian inner core chu moisture leh wear lakah a veng a, long-term dimensional stability a tichiang a ni.
Rigid Understructure chu a awm a:Adjustable steel pedestals hian height dik tak a siam a, snap-on emaw bolted stringers hian lateral grid stability a pe thung.
Modular Panel lakchhuah theih te:Panel pakhat zel chu a chhehvel infrastructure tibuai lovin maintenance atan awlsam takin a chhuak chhuak thin.
Surface Finish hrang hrang hrang hrang:Factory-applied HPL, conductive ESD vinyl, emaw project specification ang zela siam bare finish te.

 

System Structure & Composition te chu a hnuaia mi ang hian a ni

 

Surface Finish a ni:Anti-static HPL / Conductive PVC hmanga siam a ni
A chung ber Steel Sheet: 1.1.High-grade galvanized steel chuan a chunglam nghet tak a pe a ni.
Engineer-a siam Core: 1.1.High-density particle board emaw cement core rit lo emaw a ni thei.
A hnuai lam Steel Sheet:Deep-formed steel sheet a ni a, flexural rigidity atan dimples a awm bawk.
Edge Trim hmanga siam:Hrisel taka hman theihna tur leh modular alignment tight tak neih theihna turin protective edge banding a awm.
Pedestal & Stringer Network te chu a hnuaia mi ang hian a ni.Electro-galvanized steel pedestals, vibration-proof locking mechanism leh optional tubular stringers hmanga siam a ni.

 

System Load hnathawh dan

 

CISCA leh EN 12825 standard angin system kimchang (Panel + Pedestal + Stringer) anga endik a ni.

Performance Parameter a ni

FINECO chungchang sawifiahna

Test Standard a ni

Concentrated Load a ni

4.45 kN atanga 6.67 kN thleng a ni

CISCA / EN 12825 ah a awm a

Uniform Distributed Load a ni

15.0 kN/m2 atanga 23.0 kN/m2 thleng a ni

CISCA / EN 12825 ah a awm a

Rolling Load a ni

2.5 kN atanga 4.5 kN (cycle 10,000) thleng a ni.

CISCA chuan a ti a

Ultimate Load a ni

>3x Concentrated Rating a ni

Proof Load Test a ni

Deflection sang ber a ni

2.0 mm aia tlem emaw a tlukpui emaw (Under working load) .

CISCA chuan a ti a

Safety Factor a ni

3.0

Engineering Standard a ni

 

Technical lam thil chi hrang hrang

 

Thil

Technical lam chipchiar zawk

Standard Panel Size a ni

600 × 600 mm (Custom size hrang hrang a awm)

Panel Thickness a ni

30 mm atanga 35 mm thleng a ni

Steel Thickness a ni

0.5 mm atanga 0.8 mm sang-grade steel a ni

Core Material a ni

A sang-Density Particle Board / Cement hmanga siam a ni

Panel rit zawng

Kg. 13 vel – kg 16 / panel

Pedestal San zawng Range a ni

Standard: 150 mm – 1000 mm inkar a ni

Fire Performance a ni

Non-Kang thei lo / Meialh laka inven theih loh Core

Electrical atanga lo chhuak a ni

1 × 106 atanga 1 × 109 Ω (ESD nena inmil)

 

Surface Finish duhthlan tur a awm

 

A rilru a buai em em a, a rilru a hah em em bawk a. HPL:Standard data center leh control room-te tan wear-resistance sang tak a awm.
Conductive / ESD Finish hmanga tihfel theihna:Electronics siamna leh server space sensitive tak takte tan a pawimawh hle.
PVC / Vinyl hmanga siam chhuah:Technical office hrang hrang tan solution man tlawm, awlsam-to-thianghlim.
Bare Panel ah hian a awm a:Site-applied carpet emaw specialized finish emaw atana buatsaih.

 

Dilna hrang hrang

 

Data Center leh Server Room hrang hrangah:High-density cable routing leh underfloor air distribution te a awm bawk.
Electric leh Power Room hrang hrang:UPS system, battery dahna, leh switchgear te tan heavy-duty support.
Control Room leh Telecom-ah te:24/7 monitoring hub atan vibration-resistant flooring a awm.
Industrial Technical Facilities te chu a hnuaia mi ang hian a ni.Automated production line siamna tur access flooring chhe thei lo.

 

Quality Control & Thil siam chhuah dan tur

 

Raw Material enfiahna: 1.1.Steel thickness, core density, leh anti-corrosion coatings te khauh taka enfiah.
Dimensional dikna: 1.1.Laser-in a sei zawng, a squareness leh a flatness (±0.2 mm) a finfiah.
Load Testing neih dan tur:CISCA leh EN 12825 standard zawm tur random sample testing neih a ni.
Pre-Shipment enfiahna:Packaging, labeling, leh hardware kimchang leh dik loh finfiahna hnuhnung ber.

 

Installation Sequence a ni

Subfloor buatsaih dan: 1.1.Structural slab chu tifai la, level rawh.

Pedestal Layout: A chhuahna tur hmun:Pedestal te chu modular grid angin dah rawh.

A san zawng siamrem dan:Pedestal te chu Finished Floor Height (FFH) tarlan angin level rawh.

Stringer Install dan tur chu:Grid stability atan stringers te chu pedestal heads ah connect rawh.

Panel Install dan tur chu:Grid zawh tawhah panels dah rawh.

A tawp berah chuan Alignment:Overall level leh panel fit te enfiah rawh.

 

Zawhna Zawh fo thin

 

Q: He system hian server rack leh battery cabinet rit tak tak a support thei ang em?

A: Ni e. FINECO heavy-duty system hi high-density data center tan bik engineer a ni. Panel load class leh understructure chu i rack weight dik tak, footprint, leh wheel loads dik tak a zirin kan configure thin.

Q: Heavy-duty raised floor-ah chuan stringers hi tih ngei ngei tur a ni em?

A: Stringers hi a tha hle a, heavy-duty application atan emaw, floor san zawng zawh tawhin standard level a pelh hunah emaw a mamawh fo thin a, hei hian lateral stability leh rolling{1}}load performance nasa takin a tichangtlung a ni.

Q: Panel load capacity leh system load capacity hi a inang em?

A: Ni lo, raised floor-a khawvel performance tak tak chu panel, pedestal leh stringer te inzawmkhawmnaah a innghat a ni. Kan system te hi structural unit kimchang tak angin kan evaluate a, kan test bawk.

Q: FINECO hian third-party test report leh CAD drawing a pe thei ang em?

A: Ni e. Technical package kimchang tak tak kan supply a, chung zingah chuan CISCA/EN test report, product data sheet, leh CAD layout drawing te pawh a tel a, project submittal leh engineering approval te pui turin.

Q: International order siamna atana standard lead time chu engzat nge ni?

A: Lead time hi project quantity leh custom specification a zirin a inang lo (a tlangpuiin kar 2 atanga kar 4 chhung). Schedule dik tak siam turin kan sales team te hi i project scale nen zawhfiah rawh.

hot tags .: encapsulated steel rit-duty raised floor, China encapsulated steel rit-duty raised floor siamtu, supplier, factory